Trading & Supply · Fabrication & Installation · Dubai, UAE
Aluminium Products · 03

Thermal Windows & Doors


Thermally broken frames that cut heat transfer on air-conditioned buildings.

Aluminium conducts heat readily. A thermal break interrupts that path: an insulating barrier separates the outer frame from the inner one, so heat moving through the profile is slowed. In a climate like the UAE's, that difference shows up in cooling load and in the comfort of the space immediately inside the glazing.

When a thermal break earns its cost

A thermal break is a low-conductivity barrier inside the frame that separates the inner and outer aluminium. Aluminium conducts heat readily, so without it the frame becomes a direct path between a 45°C exterior and a conditioned interior.

It is worth paying for where the space behind is air-conditioned and occupied. It is usually not worth paying for in a stair core, a plant room, a service corridor or a back-of-house area that is not conditioned – and specifying it there is a common way to spend money with no return.

What the selection depends on

Glass build-up

A thermally broken frame around single glazing is a half-measure. The frame and the glass have to be selected together, or the weaker one sets the result.

Opening type

Casement, top-hung, tilt-and-turn and fixed lights behave differently for both sealing and hardware. Confirm the opening schedule before pricing.

Condensation risk

In a heavily conditioned building with humid outside air, surface condensation on the frame is the practical failure people notice. This is one of the things a thermal break is there to prevent.

Finish and exposure

Coastal exposure is harder on coatings than inland. Tell us where the building is and we will flag it if the finish looks under-specified.

What we need to quote

  • Opening schedule with sizes and types
  • Glass specification, or the performance target if not yet fixed
  • Whether the areas behind are conditioned
  • Finish and RAL reference
  • Site location – coastal or inland
  • Supply only, or supply and install

What commonly goes wrong

Frames ordered against nominal architectural dimensions rather than the surveyed opening. On a repeating apartment layout a small error repeats across every floor, and by the time it is found the whole batch is fabricated.

The other is a specification change to the glass after the frames are ordered. The glass and the frame have to match on the same drawing revision; if they diverge, one of them is wrong.

Specification noteThermal performance depends on the combination of frame, glazing and installation detail. Where a project sets a U-value or energy target, we work to the consultant's specification. Related reading: where a thermal break earns its cost.
Cutaway of a thermally broken aluminium window profile with double glazing
Related

More from Aluminium Products


01 Aluminium sliding doors framing a city view from a living space

Aluminium Sliding Doors

Large glazed openings on a rolling track, for balconies, terraces and retail frontages.

View details
Aluminium Sliding Doors
02 High-rise façade of repeating glass and aluminium panels

Curtain Wall Profiles

Mullion and transom systems that carry wind load back to the structure on tall elevations.

View details
Curtain Wall Profiles
04 Cutaway of a non-thermal aluminium window and door profile

Non-Thermal Windows & Doors

Standard aluminium frames for unconditioned areas, service zones and back-of-house.

View details
Non-Thermal Windows & Doors
05 Contemporary kitchen fitted with aluminium profile cabinetry systems

Kitchen Profiles

Handle, edge and glass-door sections for modular cabinetry and joinery work.

View details
Kitchen Profiles

Need thermal windows & doors priced?

Send quantities, sizes and the delivery location. You will get price, availability and a lead time we can hold.

WhatsApp