Aluminium Sliding Doors
Large glazed openings on a rolling track, for balconies, terraces and retail frontages.
View detailsStandard aluminium frames for unconditioned areas, service zones and back-of-house.
Not every opening needs a thermal break. For unconditioned areas, service zones, staircases, back-of-house and many standard applications, a non-thermal aluminium system delivers the same durability and finish quality at a lower cost per square metre.
| Specification | Commonly available |
|---|---|
| Material | Extruded aluminium |
| Alloy | 6063 is the usual architectural extrusion alloy; 6061 where the section is structural |
| Temper | Commonly T5 or T6, depending on the section and application |
| Finish | Mill · anodised · powder coated |
| Colour | Powder coating commonly referenced to RAL |
| Lengths | Commonly supplied around 6 m, and cut to length on request |
| System type | Standard aluminium window and door frames, without a thermal break |
Non-thermal frames are standard aluminium window and door systems without a thermal break. They suit areas that are not air-conditioned, where paying for a thermal break returns nothing.
Section dimensions, chamber depths and system performance are specific to each profile system and are confirmed against the system selected for the project.
The section as extruded, untreated. Suitable where the profile is hidden or will be coated later. Not for exposed exterior use.
An electrochemical finish that becomes part of the surface rather than sitting on it. Hard-wearing and keeps a metallic appearance. Colour range is narrower than powder coating, and matching anodised batches is harder.
A cured polyester coating, usually specified to a RAL reference. Wide colour range and good consistency, provided the whole elevation comes from one batch.
Stair cores, plant rooms, service corridors, storage, back-of-house and unconditioned commercial space are all sensible applications. The frame is simpler, lighter and cheaper, and nothing is lost because there is no conditioned air behind it to protect.
They are the wrong choice behind an air-conditioned occupied space. Aluminium conducts heat readily, and without a break the frame becomes a direct path between a 45°C exterior and the inside. The visible symptom is condensation on the frame; the invisible one is cooling load. If the space is conditioned, specify a thermal break instead.
6063 is the usual choice for architectural extrusions – it extrudes into complex sections cleanly and takes anodising and powder coating well. 6061 is specified where the section carries more load. The right alloy follows from what the profile has to do.
Where the space behind is not air-conditioned – stair cores, plant rooms, service areas, back-of-house. There the thermal break adds cost and returns nothing. Where the space is conditioned and occupied, specify a thermal break.
Generally yes, within the system's limits, but the combination should make sense. A high-performance glass build-up in a non-thermal frame is an unbalanced specification – the frame will set the result.
The profile or system type, a drawing or section reference if you have one, the alloy and finish required, the RAL reference if powder coated, total length or piece quantities, and the delivery location.

Large glazed openings on a rolling track, for balconies, terraces and retail frontages.
View details
Mullion and transom systems that carry wind load back to the structure on tall elevations.
View details
Thermally broken frames that cut heat transfer on air-conditioned buildings.
View details
Handle, edge and glass-door sections for modular cabinetry and joinery work.
View detailsTell us the project and the programme. We will confirm whether it is stock or made to order, and price it accordingly.